Заказной номер | Наименование | Описание RUS | Описание EN | Описания на сайте BOSCH | Заказ |
|
Type Z2S NS 16 21558 |
Pilot operated check valves of sandwich plate design
Nominal sizes 6 to 22
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
For the leak-free closure of one or two actuator ports, even over longer times at rest
Opening pressures:
NS 1 | | | |
|
|
Type Z2S NS 22 21564 |
Pilot operated check valves of sandwich plate design
Nominal sizes 6 to 22
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
For the leak-free closure of one or two actuator ports, even over longer times at rest
Opening pressures:
NS 1 | | | |
|
|
Pilot operated check valves of sandwich plate design 1 987 761 012 1987761012 |
Nominal sizes 6 and 10
Porting pattern to ISO 4401
Operating pressure max.: 315 bar
Flow max.: 40 to 120 L/min | - | | |
|
|
Hydraulic pilot operated check valves 1 987 760 711 1987760711 |
Nominal sizes 6 to 25
With optional drain connection
Porting pattern to ISO 5781
Operating pressure max.: 315 bar
Pilot pressure: 3 to 315 bar (NS6)
Flow max.: 60 to 90 L/min | - | | |
|
|
Type Z2SRK NS 6 21543 |
Pilot operated check valves of sandwich plate design
(210 bar series)
Nominal sizes 6 to 10
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
For the leak-free closure of two actuator ports
Opening pressure 1.5 bar
Operating pressure m | - | | |
|
|
Type Z2SRK NS 10 21549 |
| - | | |
|
|
Types M-.SED and M-.SEW NS 6 (SED) 22049 |
Nominal sizes 6 and 10
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
Leak-free isolation of closed port
Solenoids with detachable coil
The pressure-tight chamber needs not to be opened for changing the coil (SED)
Switching is ensu | | | |
|
|
Types M-.SED and M-.SEW NS 6 (SEW) 22058 |
Nominal sizes 6 and 10
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
Leak-free isolation of closed port
Solenoids with detachable coil
The pressure-tight chamber needs not to be opened for changing the coil (SED)
Switching is ensu | | | |
|
|
Types M-.SED and M-.SEW NS 10 (SED) 22045 |
Nominal sizes 6 and 10
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
Leak-free isolation of closed port
Solenoids with detachable coil
The pressure-tight chamber needs not to be opened for changing the coil (SED)
Switching is ensu | - | | |
|
|
Types M-.SED and M-.SEW NS 10 (SEW) 22075 |
Nominal sizes 6 and 10
Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
Leak-free isolation of closed port
Solenoids with detachable coil
The pressure-tight chamber needs not to be opened for changing the coil (SED)
Switching is ensu | | | |
|
|
Type KSDER1 2/2 18136-02 |
Cartridge valve
Build size 1
Direct operated directional poppet valve with solenoid operation
Closed port is leak-free
Safe switching even after long periods of time
Wet-pin DC solenoids
Coil can be rotated
With protected hand override
Leak-free on | - | | |
|
|
Type KSDER1 3/2 18136-03 |
Cartridge valve
Build size 1
Direct operated directional poppet valve with solenoid operation
Closed port is leak-free
Safe switching even after long periods of time
Wet-pin DC solenoids
Coil can be rotated
With protected hand override
Leak-free on | - | | |
|
|
Types WEH and WH 24751 |
Nominal sizes 10 to 32
Valves used to control the start, stop and direction of a fluid flow
Electro-hydraulic operation (WEH),hydraulic operation (WH)
For subplate mounting, Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
Spring or p | | | |
|
|
Valves with position switch 1 987 761 104 1987761104 |
Nominal sizes 16 and 25
Conceived in accordance with Article 1b of the Machine Directive 89/392/EEC, Version 98/37/EC
Sturdy, inductive sensor
Short-circuit-proof transistor outputs
M12 sensor connection
Operating pressure max.: 350 bar
Flow max.: 2 | - | | |
|
|
Directional spool valves, pilot operated 1 987 760 603 1987760603 |
Nominal sizes 10 to 25
Porting pattern to ISO 4401
Operating elements:
Hydraulic
Electric
Operating pressure max.: 350 bar
Flow max.: 160 to 700 L/min | - | | |
|
|
Type Z4WEH 24755 |
Nominal size 10
Pilot operated directional spool valve
Functions as; an isolating/free-flow valve or as an isolating/free-flow short circuit valve
P and T have free-flow in all switched positions
Porting pattern to DIN 24 340 form A10, ISO 4401 and CE | - | | |
|
|
Types WH and WP 22282 |
Nominal size 6
Porting pattern to DIN 24 340 form A, without locating pin hole (standard)
Porting pattern to ISO 4401 and CETOP-RP 121 H, with locating pin hole (ordering detail .../60 at the end of the valve type code)
Operating elements:
Pneumatic, | | | |
|
|
Types WMM, WMR, WMU and WMD NS 6 22280 |
Nominal sizes 6 to 25
Direct operated directional spool valve
Operating elements:
Roller/plunger, hand lever or rotary knob
Porting pattern to DIN 24340 form A, without locating pin hole (standard)
Porting pattern to ISO 4401 and CETOP-RP 121 H, with | | | |
|
|
Types WMM, WMR, WMU and WMD NS 10 22331 |
Nominal sizes 6 to 25
Direct operated directional spool valve
Operating elements:
Roller/plunger, hand lever or rotary knob
Porting pattern to DIN 24340 form A, without locating pin hole (standard)
Porting pattern to ISO 4401 and CETOP-RP 121 H, with | - | | |
|
|
Types WMM, WMR, WMU and WMD NS 16 22371 |
Nominal sizes 6 to 25
Direct operated directional spool valve
Operating elements:
Roller/plunger, hand lever or rotary knob
Porting pattern to DIN 24340 form A, without locating pin hole (standard)
Porting pattern to ISO 4401 and CETOP-RP 121 H, with | - | | |
|